The FST Remote Analytical Certification program is a cost-effective accurate alternative to standard on-line gas analysis. Our "Grab Sample" approach provides a snapshot low-level ppb analysis of impurities in Ar, N2, O2, H2, He, CDA & other gases.
Sample integrity is maintained through a proprietary testing process
Fast turn around for complete test results
Shipping complies with DOT 3A1800 regulations
Sample collection assistance available by request

Standard analysis is performed with a Trace Analytical RGA5. Upon specific request and at an additional cost, FST can perform an analysis utilizing a Gow-Mac GC/DID.
   
Standard Analysis Performed
Trace Analytical RGA 5 - Detection Limits
Sample Gas/Impurity H2 CO CO2 CH4 NMHC
Oxygen 2 ppb 1 ppb 5 ppb 2 ppb 3 ppb
Nitrogen 2 ppb 1 ppb 1 ppb 1 ppb 3 ppb
Argon 2 ppb 1 ppb 1 ppb 1 ppb 3 ppb
Hydrogen - 4 ppb 1 ppb 2 ppb 3 ppb
Helium 2 ppb 1 ppb 1 ppb 1 ppb 3 ppb
   
GC/DID - Detection Limits
Sample Gas/Impurity N2 Ar
Oxygen 50 ppb 50 ppb
Nitrogen - 10 ppb
Argon 10 ppb -
Hydrogen 10 ppb 10 ppb
Helium 10 ppb 10 ppb